EXE Cell LC-NLP configuration is a standalone system capable of detecting and monitor accurate weight measurements using DynaCell Load Cells, adaptable to any applications: LED walls, ceilings, trusses, big support, etc. lightweight solution to transport, quick to install and capable of lifting weights up to 7.5 tons.
It was necessary to combine the Flexa Sensors wireless load cell lines with a wired connection system. Wired systems have the advantage of being constantly active and allow automatic responses in safety interventions. These devices can be installed anywhere, without the worries of radio coverage and the limitations of battery life.
The design of the DynaCell combined with EXE LC-NLP technology based on wired environments is our solution for safe load control. The Network Load Processor is the central unit connecting up to 16 peripheral cells per unit. The wired mode, with instant intervention in case of emergency, is the most advanced solution for the safety of loads.
500kg – BLACK ANODIZED ALUMINIUM
5000kg – SANDBLASTED STAINLESS STEEL
Max no. of DynaCell for one NLP unit
16 cells
Max no. of NLP unit per system
2 NLP Units (= 32 cells max), with additional Ethernet Switch module
Load Detection
Continuous and instantaneous
IP Grade
IP65
Available Loads
500kg and 5000kg
Cell Body Material
500kg
Aluminium version: EX AW-2024
5000kg
Stainless steel version: AISI 630
Load accuracy
Accuracy typically ± 1% of current load or ±10 kg (whichever is the greater value)
Safety factor
8:1
Compatible Shackle To Fit In Dynacell 500kg
Standard 2.0 t, 3.25 t, 4.75 t
Compatible Shackle To Fit In Dynacell 5000kg
Standard 3.25 t, 4.75 t
Max XLR cable lenght from NLP Unit to Cells
100m
User Interface And Data Management
On-board display on NLP unit
NLP software on PC with Ethernet cable
Panel-Mount Connector
XLR 5 pin plug
It is the Central Unit for the management of the wired network. It can control up to 16 cells, each with its own XRL cable, and has the emergency stop output to the controllers.
It’s a point-to-point star wiring connection. Each unit is connected directly to the NLP, in case of malfunctions to a cable, all other connections remain active.
A color TFT display on the front shows the loads of each cell and by cell group. The unit processes the data and manages the output information. The unit is autonomous and can therefore work without a PC.
EXE Cell LC-NLP is highly reliable and quick and easy to use; it’s supplied included in the NLP16 package. It is possible to set both maximum (overload) and minimum (underload) load limits for each cell, plus maximum and minimum warning levels.
The PC can be connected directly to the NLP or Ethernet Switch module.
The NLP system includes several solutions.
The suspended loads can be read by the single DynaCell or by the EXE RISE hoists equipped with the LC-H2T CELL HOOK module with integrated load cell. The use of DynaCell can be associated with both EXE RISE hoists and with third party brand hoists.
The LC-NLP Central Unit acts as a manager of incoming load data from the cells. In case of anomalies (e.g., overload), the Safety Loop circuit is activated for immediate cutting of the power supply to the hoists.
There is a continuous wired connection between the load cells, the Central Unit, the EXE DRIVE DL Controller, and the hoists
When the LC-NLP Unit receives an overload or underload data from the cell, it instantly activates communication to the controller that interrupts the power supply to the hoist.
The EXE DRIVE DL series is fully compatible with the LC-NLP Safety Loop
ONE FOR ALL